@@ -998,6 +998,7 @@ circuit_testing_failed(origin_circuit_t *circ, int at_last_hop)
|
|
void
|
|
void
|
|
circuit_has_opened(origin_circuit_t *circ)
|
|
circuit_has_opened(origin_circuit_t *circ)
|
|
{
|
|
{
|
|
|
|
+ int can_try_clearing_isolation = 0, tried_clearing_isolation = 0;
|
|
control_event_circuit_status(circ, CIRC_EVENT_BUILT, 0);
|
|
control_event_circuit_status(circ, CIRC_EVENT_BUILT, 0);
|
|
|
|
|
|
/* Remember that this circuit has finished building. Now if we start
|
|
/* Remember that this circuit has finished building. Now if we start
|
|
@@ -1005,9 +1006,12 @@ circuit_has_opened(origin_circuit_t *circ)
|
|
* to consider its build time. */
|
|
* to consider its build time. */
|
|
circ->has_opened = 1;
|
|
circ->has_opened = 1;
|
|
|
|
|
|
|
|
+ again:
|
|
|
|
+
|
|
switch (TO_CIRCUIT(circ)->purpose) {
|
|
switch (TO_CIRCUIT(circ)->purpose) {
|
|
case CIRCUIT_PURPOSE_C_ESTABLISH_REND:
|
|
case CIRCUIT_PURPOSE_C_ESTABLISH_REND:
|
|
rend_client_rendcirc_has_opened(circ);
|
|
rend_client_rendcirc_has_opened(circ);
|
|
|
|
+ can_try_clearing_isolation = 1;
|
|
connection_ap_attach_pending();
|
|
connection_ap_attach_pending();
|
|
break;
|
|
break;
|
|
case CIRCUIT_PURPOSE_C_INTRODUCING:
|
|
case CIRCUIT_PURPOSE_C_INTRODUCING:
|
|
@@ -1016,6 +1020,7 @@ circuit_has_opened(origin_circuit_t *circ)
|
|
case CIRCUIT_PURPOSE_C_GENERAL:
|
|
case CIRCUIT_PURPOSE_C_GENERAL:
|
|
/* Tell any AP connections that have been waiting for a new
|
|
/* Tell any AP connections that have been waiting for a new
|
|
* circuit that one is ready. */
|
|
* circuit that one is ready. */
|
|
|
|
+ can_try_clearing_isolation = 1;
|
|
connection_ap_attach_pending();
|
|
connection_ap_attach_pending();
|
|
break;
|
|
break;
|
|
case CIRCUIT_PURPOSE_S_ESTABLISH_INTRO:
|
|
case CIRCUIT_PURPOSE_S_ESTABLISH_INTRO:
|
|
@@ -1033,6 +1038,17 @@ circuit_has_opened(origin_circuit_t *circ)
|
|
* This won't happen in normal operation, but might happen if the
|
|
* This won't happen in normal operation, but might happen if the
|
|
* controller did it. Just let it slide. */
|
|
* controller did it. Just let it slide. */
|
|
}
|
|
}
|
|
|
|
+
|
|
|
|
+ if (can_try_clearing_isolation && !tried_clearing_isolation &&
|
|
|
|
+ circ->isolation_values_set &&
|
|
|
|
+ !circ->isolation_any_streams_attached) {
|
|
|
|
+ /* If we have any isolation information set on this circuit, and
|
|
|
|
+ * we didn't manage to attach any streams to it, then we can
|
|
|
|
+ * and should clear it and try again. */
|
|
|
|
+ circuit_clear_isolation(circ);
|
|
|
|
+ tried_clearing_isolation = 1;
|
|
|
|
+ goto again;
|
|
|
|
+ }
|
|
}
|
|
}
|
|
|
|
|
|
/** Called whenever a circuit could not be successfully built.
|
|